© Copyright eSite Power Systems AB 2021. All rights reserved.
No part of this document may be reproduced in any form without the written permission of the copyright owner. The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. eSite Power Systems AB shall have no liability for any error or damage of any kind resulting from the use of this document.
https://www.clearbluetechnologies.com/
E-mail: [email protected]
Phone: +1 647 748 4822
Clear Blue Technologies 30 Lesmill Road, Unit 7 Toronto, ON, Canada M3B 2T6
Add support for expansion solar units
Updated SNMP with expansion solar unit information
Possible to select between ACDC expansion unit and ACDC+Solar expansion unit
Fixed Solar VPMG calculation in SNMP communication interface
Charge balancing of lithium-ion batteries.
Periodic Balancing Full Charge of lithium-ion batteries.
Charge Synchronization of lithium-ion batteries.
Add Hybrid Shifting and Peak Load Shifting functions on lithium-ion batteries.
Dedicated and improved SOC calculation algorithm that always keeps track on SOC for Li-ion batteries, even if communication to BMS is lost. This improves robustness and makes sure that the Li-ion battery bank is charged at the right moment.
Dynamic float charge function that maximizes the life of the battery bank in cases where the battery bank remains fully charged for prolonged periods of time.
Improved pre-charge function that limits inrush currents that otherwise would have tripped battery breakers, a well-known problem for Li-ion battery banks.
New Green Power Influx feature, AC Power Minimization.
Add Tenant ID 0.
Temperature derating on Linux-CPU temperature.
Update to SNMP v. 1.4
Improved current limitation when communicate with lithium-ion batteries.
Add Event to Reset old alerts from eSite Tools.
Integration of Incell SLB48 lithium-ion.
Increase num. of integrated BMU,s from 12 to 16.
Integration of Shoto SDA10-48100P lithium-Ion.
Automatic conversion of old custom battery files.
Fix time different between site and Tools server
Update manuals with appendix.
Fix Wi-Fi disconnect problem. (only 13.10.0)
Add Auto Reconnect of Tools agent handler. (only 13.10.0)
Improve Start-up sequence on lithium-ion batteries.
SNMP v. 1.6
Update to SNMP v. 1.5
Improve alarm handling.
Update Shoto integration to Modbus register version 1.2.
Update Modbus server register to 4.0.
Fix Modbus com error to genset AMF panels.
Remove dual chemistry function from Web GUI. Not supported any more.
Integration of Sacred Sun lithium battery
SNMP - Add read write support for v1/v2
Changes in Modbus-handler to support communication to battery and AMF panel at the same time. Remove Modbus over TCP support.
Add 3 more tenant-monitoring
eAgent - change name time zone and ambient temp in Tools
Change battery configuration web pages to use battery template.
Add 8 configurable digital inputs.
The function "Mixed Battery Chemistry is deprecated and will be deleted in future release.