1 General Information

1.1 Document focus

This document describes how to install and commission the eSite Modular system. It focuses on the installation process of the eSite Modular system components and mentions the associated systems only in brief.

The scope of the document covers the Remote Monitoring and Control (RMC) unit, the Power Combiner Unit (PCU) and the eSite Modular RE, RSE and SE Converter Units.

1.2 Target group

This document is intended for personnel that will perform the installation and the Site Commissioning of the eSite Modular system. All involved personnel must have sufficient basic skills and training.

1.3 Warning levels

Note

Highlights general useful information.

1.4 Trademarks

eSite™ and eSite Tools™ are registered trademarks of eSite Power Systems AB (publ) and will be referred to hereafter as eSite and eSite Tools.

1.5 Available product documentation

eSite Modular documentation

Product Description

Installation & Site Commissioning Manual

Operation Manual

1.6 Abbreviations and definitions

The following glossary list contains abbreviations and definitions commonly used in the eSite Modular documentation.

1.6.1 Abbreviations

Abbreviation
Description

A

Ampere

Ah

Ampere hour

AC

Alternating Current

ATS

Automatic Transfer Switch

BMS

Battery Monitoring System

BMU

Battery Monitoring Unit

°C

Degree Celsius

CAN

Controller Area Network

CE

Conformité Européenne

DC

Direct Current

EC

European Conformity

EMC

Electromagnetic Compatibility

GND

Electrical Ground

HP

High Priority

Hz

Hertz

kW

Kilowatt

LAN

Local Area Network

LP

Low Priority

MCB

Miniature Circuit Breaker

MPPT

Maximum Power Point Tracker

MHz

Megahertz

N/A

Not Available

NTP

Network Time Protocol

PVC

Polyvinyl chloride

RMS

Remote Monitoring System

SCR

Silicone controlled rectifiers

SoC

State of charge

SIM

Subscriber Identity Module

V

Volt

V AC

AC Volts of Alternating Current

V DC

DC Volts of Direct Current

W

Watt

WLAN

Wireless Local Area Network

1.6.2 Definitions

Definition
Description

Associated systems

The term 'associated systems' refers to parts or systems not manufactured by eSite Power Systems that are connected to the eSite Modular system, e.g. solar arrays, the battery bank, AC power sources, etc.

Customer load

The customer load is the equipment that is supplied with power from the eSite Modular system.

Tenant

A tenant is a customer whose equipment is part of the customer load. Each tenant may connect equipment as LP and/or HP load. Power consumption may be measured separately for each connected tenant.

Converter Unit

The Converter Unit contains power electronics control system of eSite Modular. It includes rectifiers and solar converters and is mounted outside of the battery cabinet. Max 3 units can be mounted on the system. The Converter Unit must not be opened.

Power Combiner Unit

The Power Combiner Unit (PCU) is the user point of access to the eSite Modular system where all power connections are managed.

RMC

The remote monitor controller (RMC) is located at the top of the battery cabinet. Signal cables and control cables are connected to the RMC, front and back.

eSite Tools

eSite Tools is an RMS that monitors several eSite Modular systems in a network. eSite Tools can be used to view the status of all connected sites in a network and to create a variety of reports. It can also be used for software upgrades, data downloads and configuration changes.

eSite Web

eSite Web is the local eSite Modular web browser interface. It can be reached on-site via the local Ethernet LAN and WLAN connections.

1.7 Compliance

eSite Modular is a carefully designed product that has undergone rigorous performance testing with regards to quality, environment, electrical safety and functionality.

This product and the system software has complied to and met the test standards of:

  • ETSI EN 300 386 V1.6.

  • ETSI 300 019-1-2 Class 2.

  • IEC/EN 60950-1:2005+A1+A11+A12+A2

  • IEC/EN 60950-22:2006-A11

1.8 CE-marking

eSite Modular complies to the CE standards. EC (European Conformity) labels are found on the side of the Converter Units.

1.9 Product numbering

eSite Modular product number (P/N) of the Modular:

Product Label
Description
Comment/Number

RSE

Converter Unit with Rectifiers and Solar converters

Used for AC power (grid and/or genset) and solar DC power. Serial number 7347xxx

RE

Converter Unit with Rectifiers only

Used for AC power (grid or/and genset) only. Serial number 7370xxx

SE

Converter Unit with Solar converters only.

Used for solar DC power only. Serial number 7400xxx

RMC

Remote Monitor and Controller unit.

Serial number 7410xxx

PCU

Power Combiner Unit Default MCB configuration 3 x 125A, 3 x 32A, 3 x 6A.

1.10 Authorization

Note

Local authorization regulations for work with electrical equipment must always be obeyed.

An unapproved user:

  • can work with the eSite Modular system only during regular operation.

  • can pereform the initial analysis if an alarm is activated.

  • can log in to eSite Tools or the eSite Web to view information and alarms.

  • can not make changes or configurations in eSite Tools or the eSite Web.

An approved user*:

  • has the sufficient basic competence that the market requires and has attended an approved eSite training.

  • can install the eSite.

  • can perform Site Commissioning of the eSite.

  • can work with live equipment.

  • can replace units.

  • can configure the system.

  • can perform troubleshooting.

*depending on level of training.

1.11 Support

eSite Power Systems operate a 'Service Desk & Knowledge Base', where the Customer can access certain documentation, guides and software, report Issues and request support/resolution of reported Issues.

The Customer may access the 'Service Desk & Knowledge Base' by using a user account (provided by the Supplier). The Service Desk is a single point of contact between the Supplier and the Customer and can be found here:

http://servicedesk.esitepowersystems.com

When reporting Issues or requesting support, the Customer is asked to fill in the appropriate form and describe the problem/request in detail. If applicable, photographs and/or log files may be attached to the request.

Copyright © 2022 eSite Power Systems AB

Last updated

Was this helpful?